446100, Russia, Samara region, Chapaevsk, Kuibyshev str., 1  

NSI «PULSAR»

PULSAR non-electrical system of initiation. TU 20.51.12-021-43918744-2024

The PULSAR NSI is designed to conduct blasting operations on the ground and in underground workings that are not dangerous for gas and/or coal (shale) dust at ambient temperatures of minus 500С to plus 650С.

NSI "PULSAR" is used for initiating detonator checkers, emulsion cartridges sensitive to the cap, ammonite 6GV cartridges or other industrial explosives approved by Rostekhnadzor, as well as for initiating the explosive chain.

Depending on the detonator capsule used and the waveguide length, NSI PULSAR include:

  • NSI "PULSAR" SK – detonator capsules with deceleration in the range 0 – 900 ms, are designed for initiating charges during explosion work on the ground surface, according to the conditions of use belongs to products based on explosives class "Special" (C), group 1;
  • NSI "PULSAR" SD - Capsule-detonators with deceleration in the range 0-8000 ms, are designed for initiating charges during mining operations in underground workings, not dangerous for gas and/or coal (shale) dust, according to the conditions of use belongs to products based on explosives class "Special" (C), group 2;
  • NSI "PULSAR" P – microcapsule in the group connector with a response time of 0 to 200 ms; are designed for installation of explosive networks during explosion work on the ground surface, according to the conditions of use belongs to products based on explosives class "Special" (C), group 1.
Basic physico-chemical and explosive characteristics: 
№ п/п

Name of indicator

Результат испытаний

1.

Appearance

A hermetically sealed cylindrical shell made of metallic material with a tail made of polymer material and an extending long tube made of three-layer polymer material.

2.

Diameter of the detonator capsule and microcapsule not exceeding, mm

8,0

3.

Length of detonator capsule not exceeding, mm

95

4.

Length of microcapsule, mm

61-65

5.

The process speed in the impact tube shall be, m/s

1800-2200

6.

Detonator caps of types SK and SD must penetrate lead plates according to GOST 3778-98 with a thickness of (5.0±0.1) mm

Withstand

7.

Microcapsule P must penetrate lead plates according to GOST 3778-98 with a thickness of (2.0 ± 0.1) mm

Withstand
8.

The detonator capsules shall be water resistant and remain operational after exposure in an aqueous medium with a pH of 3 to 9:

  • is P at a hydrostatic pressure of 0.01 MPa (0.1 kgf/cm2) for 24 hours;
  • SK, SD, at a hydrostatic pressure of 0.3 MPa (3 kgf/cm2) for 14 days.
Withstand
9.

Under the influence of a static load of 5.0 ± 1 kgf on the impact tube connection to a detonator capsule or microcapsule

Withstand

without breaking the structure

10.

Detonator capsules shall be safe during transport and shall retain their performance after shaking for (10 ± 1) minutes at a frequency of (60 ± 1) impact per minute from a height of (50 ± 1) mm

Withstand

without breaking the structure

11.

The detonator capsule shall remain operational at the impact tube elongation of at least %

150

12.

The shock wave tube of the capsules shall be able to withstand, with integrity (without bursting), the application of a static load of at least kgf

13,0

13.

Sensitivity to detonation under the influence of the initiating impulse of starting devices, detonating cords with a core mass of at least 6 g per meter length, electric detonator ED-8M or similar in characteristics approved by RTN

Complete

 

Technical requirements: 
  1. The non-electrical initiation system "PULSAR" shall meet the requirements of the technical conditions and the requirements of TR TC 028/2012 "On the safety of explosives and products based on them".
  2. The detonator capsules used in the PULSAR system shall, in appearance, conform to the requirements of the design documents and control samples approved in accordance with the established procedure.
  3. The following materials shall be used for the construction of the PULSAR system:
  • The type of main explosive in the detonator capsule is TEN;
  • In the PULSAR SK system, detonators with an explosive mass in the detonator between 0.92 g and 1.8 g with a deceleration time between 0 and 900 ms rated shall be used: 0, 50, 75, 100, 125, 175, 200, 225, 300, 400, 450, 600, 700, 750, 800, 900 ms;
  •  In the PULSAR SD system, detonators with an explosive mass in the detonator from 0.92 g to 1.8 g with a deceleration time in the range of 0 - 8000 ms nominal shall be used: 0, 500, 1000, 1500, 2000, 2500, 3000, 3500, 4000, 4500, 5000, 6000, 7000, 8000 ms;
  • In the PULSAR P system, detonators shall be used with an explosive mass in the detonator of at least 0.2 g with a deceleration time in the range 0 - 200 ms nominal: 0, 9, 17, 25, 42, 67, 109, 150, 176, 200 ms.
  • The PULSAR system shall use the shock wave tube "PULSE" according to TU 20.51.12-023-43908744-2024 with a length from 2 meters, according to the order of the consumer, with 1 meter increments;
  • Crimp sleeve with a length of 20 mm to 50 mm according to STO 43908744-71-2023 or according to NTD, ensuring the hermeticity and density of the connection between the shock wave tube and the capsule.
  • Universal Shock Tube Connector 'UVT-DSH' according to NTD, used for connecting the shock wave tube to the detonating cord;
  • Surface connector according to NTD, used for connecting the shock tube with the microcapsule to several shock wave tubes for transmitting the detonation impulse from the Detonating Cord.
Transportation: 

1  Detonators manufactured and packed in accordance with the specifications may be transported over any distance by all modes of transport in accordance with the regulations in force for the transport of dangerous goods for the mode concerned, which have been duly approved.

2  The PULSAR system is classified in Class 1, Division 1.1, Compatibility Group B, Classification Code 1.1B according to GOST 19433-88 in terms of storage and transport hazards.

The UN number is 0360 and the symbol number is 102.

When special packaging is used, detonators are classified in Class 1, Division 1.4, Compatibility Group S. UN number 0500.

Emergency card for transport by rail No. 143. Emergency code 24E.

3 The detonators shall be stored in the manufacturer's packaging in warehouses meeting the requirements of the "Safety Regulations for the Production, Storage and Use of Industrial Explosive Materials".

Packaging: 

The PULSAR system is packed in transport containers in accordance with the requirements of GOST R 51615–2000.

Corrugated box 4G shall be used as transport containers in accordance with regulatory and technical documentation approved in accordance with the established procedure.

Warranty period of storage: 

The warranty period for the storage of detonators in the manufacturer's packaging shall be calculated from the day of manufacture and shall be 3 years.